Photoelectric Smoke Detectors

Click here to get a free quote and protect yourself

 

ECONOMY CLASS DETECTORS

Smoke Sensitivity: 2.66+/-1.11%/FT Obscuration (UL Standard)
Power supply: 9V battery; 100/110/120/220/230/240 VAC, 50/60HZ for AC versions
Battery Life: at least 18 months under normal conditions with GP Green Cell Battery
Low Battery Life: up to 30 days warning signal Alarm Indicator:
UL listed LED, continuously emitting red light
Alarm Sound Level: exceeding 85dB at 10 feet
Operating Temperature Range: 0¢XC to 50¢XC
Humidity: 10 to 85% RH, no condensation or icing Protection of Bug Screen:
UL standard stainless chemical etching screen


PREMIER CLASS DETECTORS

Photoelectric smoke sensor - fixed tempeture - rate of rise heat sensor
Built-in sounder - 85db
Built-in fixed temperature - 135 deg F. / rate-of-rise 15 deg F. / min heat sensor
Learn mode technology
Tamper switch Field-replaceable optical chamber
LED shows visual status
Drift compensation increases immunity to dust
Large test and silence button
Clean Me™ self-diagnostics feature performs a daily full diagnostic test
Duracell 3V Lithium 123, Panasonic Lithium CR123A, Sanyo Lithium CR123A
Low Battery Threshold 2.70V causes low battery signal
Sensitivity 2.2%


PREMIER CLASS DETECTORS

 

The Photo Electric Detector shown is a  single station battery operated smoke detector. Code requires one per living level, close proximity to sleeping quarters out side the bed room. However to save lives we recommend that photo electric detectors also be placed in the bedroom of occupied bedrooms, as well as hall outside bedroom and one per living level.

These units also are available hard wired 110 and low voltage. In a fire you only have one chance to get it right. Do it before it happens
Operates on the photoelectric light scatter principle.
LED light source (estimated 40-year life).
1/8% smoke density to activate.
Utilizes solid-state components.
Samples air for smoke every 4-5 seconds.
First sight of smoke, sample rate increases 8x normal rate.
Low-battery indicator notifies when battery replacement is necessary.
Test 1 simulates smoke.
Test 2 high sensitivity test.
Power-on light.
Loud pulsating alarm sound.
No radioactive material used.
Will not alarm to gases or to aerosols.
Will not false alarm to high air flows.
Fast response to a slow smoldering fire.
Minimum maintenance required.
Fully washable.
Extended warranty.
Fire damage replacement.
Underwriter’s Laboratories (U.L.) listed.
Sold only in the home by trained fire safety specialists.
Installed in approximately 80% of all U.S.
commercial airliners.


>